Web-based IPMI management platform — monitor sensors, control fans, manage power, all from your browser.
Documentation: docs.ipmideck.com
Features • Quick Start • Documentation • Configuration • Supported Hardware
IPMIDeck is a self-hosted dashboard that connects to your servers' BMC (Baseboard Management Controller) via IPMI. It provides real-time sensor monitoring, intelligent fan curve control (FanPilot), remote power management, and hardware event logs — no CLI required.
- Real-time temperature, fan RPM, voltage, and power consumption
- Live charts with historical data (up to 1 year)
- Configurable alert thresholds with browser notifications
- Visual drag-and-drop fan curve editor
- Built-in profiles: Silent, Balanced, Performance, Full Speed, Custom
- Configurable hysteresis to prevent fan oscillation
- Safety override: fans go to 100% above critical temperature
- Autonomous loop — works independently of the dashboard
- Power On, Soft Off, Hard Off, Reset, Power Cycle
- Real-time power status indicator
- Confirmation dialogs for destructive actions
- Full command audit log
- View BMC hardware event log with severity filtering
- Search, date range filters, export to CSV/JSON
- Serial numbers, part numbers, manufacturer info
- Board, chassis, and product data at a glance
- Manage multiple BMCs from a single instance
- Panoramic view with status overview of all servers
Pull from Docker Hub (primary registry):
docker pull devluigi06/ipmideck:latest
# Linux (reaches BMCs on your LAN via UDP 623):
docker run -d --name ipmideck --network host \
-v ipmideck-data:/data \
devluigi06/ipmideck:latest
# Windows / macOS (Docker Desktop has no host networking — map the port instead):
docker run -d --name ipmideck -p 3000:3000 \
-v ipmideck-data:/data \
devluigi06/ipmideck:latestOr with Docker Compose:
docker compose up -d # pull&go (docker-compose.yml)
docker compose -f docker-compose.dev.yml up --build # build from sourceOpen http://<your-ip>:3000 and follow the setup wizard.
--network host(Linux) lets the container reach BMCs on your local network via UDP 623. On Windows/macOS use-p 3000:3000.
pip install ipmideck
ipmideck startRequires ipmitool installed on the system.
Full documentation lives at docs.ipmideck.com — start with the Getting Started guide. The docs cover installation, first-run setup, per-vendor Enable IPMI guides (Dell iDRAC, HPE iLO, Supermicro, Lenovo XCC, IBM IMM), configuration, the CLI and interactive console, the FAQ, and troubleshooting.
| Component | Technology |
|---|---|
| Backend | Python / FastAPI / Uvicorn |
| Frontend | React / Vite / TypeScript / Recharts |
| Styling | Tailwind CSS |
| Database | SQLite (aiosqlite) |
| IPMI | ipmitool (subprocess) |
| Packaging | Docker / pip |
Configuration is auto-generated at first run at /data/config.yaml (Docker / Linux) or ./data/config.yaml (Windows). Override the data directory with IPMIDECK_DATA_DIR.
A documented subset of settings can be overridden with IPMIDECK_-prefixed environment variables:
IPMIDECK_SERVER_PORT=8080
IPMIDECK_IPMI_POLL_INTERVAL=30
IPMIDECK_LOGGING_LEVEL=info
IPMIDECK_DATA_RETENTION_DAYS=180Every key is written to that config.yaml on first run — read it for the full list. The same
settings are also editable at runtime from the in-app Settings page.
Launched on a host with an attached terminal (a TTY — e.g. ipmideck start run directly, not under Docker, systemd, or a pipe), IPMIDeck opens an interactive operator console: a pinned header with keybindings above a live, streaming log. From it you can cycle log verbosity, inspect active sessions and configured servers, print the access URL, change the bind address, and restart or quit — without leaving the terminal.
Keys: [v] verbosity · [c] sessions · [s] servers · [u] url · [g] update · [b] change bind · [r] restart · [q] quit · [ESC] back. The console is not shown when IPMIDeck runs under Docker, systemd, or with piped output — there it logs plainly to stdout.
The hosts shown are RFC5737 documentation addresses, not real servers.
See the Interactive Console docs for full details.
Hardware identifiers are synthetic and the hosts shown are RFC5737 documentation addresses.
- Python 3.11+
- Node.js 20+ (for frontend development)
- ipmitool
git clone https://github.com/ipmideck/IPMIDeck.git
cd IPMIDeck
# Backend — run from the repo root (pyproject.toml lives here)
python -m venv .venv
source .venv/bin/activate # Linux/Mac
# .venv\Scripts\activate # Windows
pip install -e ".[dev]"
# Frontend
cd frontend
npm install
npm run dev# Backend — from the repo root (serves API + static frontend build)
uvicorn backend.main:app --reload --port 3000
# or: python -m backend.main --reload
# or: ipmideck start --reload (after `pip install -e ".[dev]"`)
# Frontend dev server (with HMR, proxies API to backend)
cd frontend
npm run devipmideck/
├── backend/
│ ├── main.py # FastAPI app + lifespan + CLI entry point
│ ├── console.py # interactive TTY operator console
│ ├── core/ # database, auth, crypto, config, branding, events,
│ │ # websocket, modules (loader), ipmi_service, ipmi_demo
│ ├── api/ # auth / server / dashboard / system / module routes
│ ├── models/ # Pydantic schemas
│ ├── modules/ # self-contained feature modules
│ │ │ # (manifest + routes + tasks + migrations each)
│ │ ├── sensors/
│ │ ├── fanpilot/ # + engine.py (curve / hysteresis / safety override)
│ │ ├── power/
│ │ ├── sel/
│ │ └── fru/
│ └── static/ # compiled React SPA (build artifact — do not hand-edit)
├── frontend/
│ ├── src/
│ │ ├── pages/ # Dashboard, FanPilot, SEL, FRU, Settings, Login, Setup
│ │ ├── components/ # common/, dashboard/, layout/
│ │ ├── modules/ # per-module widgets (sensors, fanpilot, power)
│ │ ├── stores/ # Zustand stores
│ │ ├── hooks/ # useWebSocket, useKeyboardShortcuts, …
│ │ ├── i18n/locales/ # 12 language catalogs
│ │ ├── api/ # HTTP client
│ │ ├── lib/
│ │ └── styles/
│ └── vite.config.ts
├── scripts/ # rebuild-spa, check-spa-built, check-i18n-parity,
│ # check-wheel, lint-workflows, smoke-docker
├── tests/ # unit/, integration/, fixtures/ipmi/
├── Dockerfile
├── docker-compose.yml
├── docker-compose.dev.yml
├── .dockerignore
└── pyproject.toml
- Local authentication with bcrypt password hashing
- Opaque session tokens, HMAC-SHA256 signed with a per-install secret, with configurable expiry
- BMC credentials encrypted at rest with AES-256-CBC. The 32-byte key is randomly generated and
stored in
<data_dir>/encryption.key— deliberately outside the database, so a stolen DB alone decrypts nothing (back the key file up separately) - BMC passwords are never placed on the command line —
ipmitoolreads them from the environment (-E/IPMITOOL_PASSWORD), so they never appear inps - No external network dependencies — fully offline capable
- ipmitool arguments are passed as a list, never through a shell (no shell-injection surface)
- Optional HTTPS/TLS for the dashboard, with one-click self-signed certificate generation
Sensor monitoring, power control, SEL and FRU work on any server with an IPMI 2.0 BMC.
Fan control (FanPilot) is vendor-specific. The table below is the honest support matrix — it mirrors the vendor profiles the app actually ships, and the same tier badges appear in the vendor picker when you add a server:
| Vendor | Fan control | Tier | Notes |
|---|---|---|---|
| Dell PowerEdge (iDRAC) | Yes | Tested | Raw iDRAC fan commands, validated on real hardware (PowerEdge R720) |
| Supermicro (X10+) | Yes | Experimental | Both fan zones |
| IBM System x (IMM) | Yes | Experimental | Dual fan bank |
| HPE ProLiant (iLO) | No | Monitoring-only | iLO exposes no IPMI fan-control interface |
| Lenovo ThinkSystem (XCC) | No | Monitoring-only | No reliable in-band restore path |
| Generic / unknown BMC | No | Monitoring-only | Never issues raw vendor writes it cannot verify |
Monitoring-only vendors still get full sensor, power, SEL and FRU support — FanPilot simply leaves their fans under BMC control rather than sending raw commands it cannot confirm.
Luigi Tanzillo — github.com/dev-luigi